Pentair control panel not commanding pumps
Pentair control panel not commanding pumps













SymptomĬould be accompanied by “bumping” noises. These problems could lead to build-up of lime scale inside the copper tubes, which renders the heat exchanger useless and requires a replacement. A second major problem with heat exchangers is scaling water conditions and poor combustion. Leaking heat exchangers are often confused with sweating or condensating heat exchangers. Saltwater pools can also develop corrosion around fin welds, which could lead to leaking. Cupro Nickel heat exchangers can be used for much greater resistance to the effects of salt water corrosion. The biggest fear about the heat exchanger is that corrosion can occur to the relatively soft copper finned tubes, causing them to develop pinhole leaks. Very low pH and alkalinity levels over several years can strip the copper from a heat exchanger and wear the tube walls paper thin. Verify burner flame is properly grounded. Reduce strength of exhaust vent and/or number of elbowsĬombustion appears normal, but the flame does not stay lit.Ĭheck for wet or damaged igniter with low resistance to ground. See page 16 and verify the gas regulator is -0.2″ wc.īurner pulsates or surges, especially on ignition. See page 15 erify the gas regulator is -0.2″ wc.Ĭontact a qualified technician or service agency to replace the gas orificeĮxhaust may have an acrid smell, or the burner may fail to stay lit. Verify pressure tap between gas valve and blower inlet. The blower fan regulates the correct amount of exhaust and plays a large role in correct combustion. The burner is located in the center of the combustion chamber, wrapped by the circular copper heat exchanger tubes. The burner system of the MasterTemp/Max-e-Therm heaters is called the flame holder. Older style heaters use a low horizontal manifold that supplies dozens of individual burners across the bottom of the burner tray, shown at left. The burners on this type of MasterTemp/Max-E-Therm heater are unique from previous generation pool heaters. Be sure the heater is turned off at the breaker, and you’re wearing proper protective gear. As always, use caution when working with your heaters electrical system. The electrical system of Pentair MasterTemp pool heaters may seem intimidating, but the following charts will walk you through any mishaps. Pentair MasterTemp Electrical Troubleshooting:

#PENTAIR CONTROL PANEL NOT COMMANDING PUMPS CODE#

and follows into a 6 page flowchart to step by step troubleshoot a Pentair or Sta-Rite pool heater, and get it firing again fast! Code Our Pentair MasterTemp troubleshooting guide starts with the error codes shared by both models. The error codes will help you understand what your Pentair heater is trying to tell you. Even the new MasterTemp above ground pool heater has the same design, and the same troubleshooting procedure. The controls and circuit boards for the Max-E-Therm and the MasterTemp are fairly identical. Troubleshooting the stacked exchanger type of heater is not much different than other electronic or digital pool heaters. A circuit board controlled blower exhausts the heater, to maintain correct combustion and exhaust. Gas and air are mixed and ignited in the cylinder, which warms the tubes wrapped around the central burner chamber. The water circulating through the copper heat exchanger tubes absorbs the heat, and exits the heater a few degrees warmer than when it entered.īy contrast, the Sta-Rite Max-E-Therm pool heater design, now adopted by Pentair, has stacks of circular heat exchanger tubes, surrounding a combustion cylinder.

pentair control panel not commanding pumps

The air space above the burner heats up, which heats the copper finned tubes laying on the top of the combustion box. Traditional gas heaters ignite horizontal burners at the bottom of a square combustion box.

pentair control panel not commanding pumps

Pentair MasterTemp and Sta-Rite Max-E-Therm Heaters

pentair control panel not commanding pumps

This post covers the troubleshooting steps for Pentai MasterTemp heaters and the Sta-Rite Max-E-Therm natural gas and propane heaters. Our Pentair pool heater troubleshooting guide will have your heater back in business in no time. Are you experiencing issues with your Pentair pool heater? Don’t stress! Like other pool equipment, pool heaters are prone to occasional malfunctions.













Pentair control panel not commanding pumps